CL-Series BatteryLink™ Automatic Charging Relay (Current Limiting) with Overcurrent Protection

CL-Series BatteryLink™ Automatic Charging Relay (Current Limiting) with Overcurrent Protection

thumbs182/7600_182x182.jpg
    DISCONTINUED PRODUCT
    Note: 7600 is replaced by 7610
  • Automatically combines battery banks during the charging cycle and isolates under discharge
  • Limits current flow allowing smaller wire size
  • Adjustable high voltage disconnect
  • Adjustable low voltage disconnect and combine voltages
  • Activates from any charging source—alternators, battery chargers, or solar panels
  • Senses charge voltages on up to two battery banks
  • Ignition protected—safe for installation aboard gasoline powered boats
  • Noise free circuitry will not interfere with other devices
  • Low current draw when closed: <0.2A

Specifications

Continuous Rating 60 Amperes DC
7 Minute Rating 90 Amperes DC
2 Minute Rating 120 Amperes DC
Voltage Rating 16 Volts DC for 12 Volts DC Nominal Systems
Current Limiting 60A at 25° Ambient
Stud Terminal Size 3/8" (M10)
Contact Form SPST-NO
Mechanical Life 1,000,000 Cycles
Coil Circuit Input Voltage 9-16 Volts DC Maximum
Automatic Operation Combines when the higher battery has remained at the required voltage for at least 30 seconds. Disconnects when the voltage drops below the charging voltage to prevent accidental discharge of a battery bank.

Certifications & Agency Standards

  • CE Marked
  • Meets SAE J1171 external ignition protection requirements

Product Line

PN Description Weight Lb (Kg)
7600
CL-Series BatteryLink™ Automatic Charging Relay (Current Limiting) with Overcurrent Protection
0.85 (0.39)